Fire & Smoke Control Systems

Fire and smoke control systems are critical life and safety.

›

›

Fire & Smoke Control Systems
H&V_Service_Fire_and_Smoke_Control_Systems

About the service

Fire and smoke control systems are critical life-safety installations and require regular inspection, testing and maintenance to ensure that they remain capable of performing their intended function.
Our commissioning process is structured around establishing that systems have been correctly set to work, regulated and tested and that the required operating conditions have been achieved. For air distribution systems, our methodology can be aligned with CIBSE Commissioning Code A: Air Distribution Systems (2024), which covers the setting to work, functional testing and regulation of ventilation and ductwork systems. CIBSE also identifies the importance of commissioning planning, system inspection, functional testing, regulation, performance testing and documentation. Where appropriate, BSRIA BG 49 – Commissioning Air Systems and other relevant industry guidance can also be considered alongside the project specification and design requirements.
Our Services Include
Heating Testing & Commissioning
Ventilation Testing & Commissioning
AHU / HRU / Fan PPM
Airflow measurement and balancing
Fan performance checks
System regulation
Pressure testing
Temperature measurement
Control and interlock checks
Functional performance testing
Re-commissioning of existing systems

What we offer

globe
AOVs & Smoke Ventilation
We inspect and test Automatic Opening Vent systems and associated smoke ventilation equipment, including controls, actuators, fans and associated components. Testing can include functional operation and verification of system sequences to establish that the installation responds correctly to the relevant activation conditions.
star
Smoke Extract Ventilation
We provide testing and verification of mechanical smoke extract systems, including associated fans, dampers, controls and ventilation components. Testing can incorporate airflow and pressure measurements, functional checks and verification against the available design criteria.
Group 27078
Car Park Extract & Smoke Control
Car park ventilation and smoke extract systems require regular inspection and testing due to their role in both day-to-day ventilation and, where designed for this purpose, smoke control. We can undertake testing of associated fans, controls, dampers and system operation, providing clients with documented results and identification of any areas requiring further investigation.
globe
Stair Pressurisation
We undertake performance testing of stair and escape-route pressurisation systems. Testing can include pressure differential measurements, airflow assessment, door condition checks and verification of system operation and control sequences. For applicable smoke-control and pressure-differential systems, testing may be undertaken with reference to the relevant sections of the BS EN 12101 series, together with the project design criteria and applicable fire-safety requirements.
globe
Smoke Curtains
Inspection and operational testing of smoke curtain systems can be undertaken to establish that equipment deploys and operates correctly and that associated controls and interfaces are functioning as intended.
star
HVAC Testing & Commissioning
We provide testing, commissioning and verification services for heating, ventilation and air-handling systems.
About Our Process
We can provide support throughout the commissioning and handover process. Our procedures are designed to ensure that works are properly planned, recorded and reported, providing clients with confidence in the results obtained. The objective is to provide documentation that remains useful to the building owner and facilities management team throughout the operational life of the installation.
1
Planning
Establishing the scope of testing, required documentation, programme and access requirements before works commence.
2
Inspection
Reviewing installations and identifying issues that may prevent successful testing or commissioning.
3
Testing
Carrying out functional and performance testing using appropriate calibrated instrumentation and agreed procedures such as test sheets, inspection records, remedial recommendations and more.
4
Verification
Reviewing results against the applicable design criteria, specifications, standards and system requirements.
5
Remedial Support
Providing clear information regarding defects or performance issues so that remedial works can be effectively targeted.
6
Re-Testing
Returning to site where required to verify that identified issues have been rectified and that the system subsequently achieves the required performance.
7
Documentation
Providing clear records of testing and verification to support project completion, handover and future maintenance.
8
Quality Assurance
Quality and traceability are fundamental to effective testing and commissioning.

Explore Our Commissioning Services​

From clean air validation to fire damper operational testing. Discover the specialist services we deliver nationwide.

H&V_Service_Fire_and_Smoke_Control_Systems

Fire & Smoke Control Systems

Fire and smoke control systems are critical life and safety.

H&V_Service_Maintenance_Compliance_and_PPM_Testing

Maintenance Compliance & PPM Testing

We provide specialist testing and specialist building services systems.

Fire damper installed within a commercial ventilation system

Fire Damper

Annual fire damper testing, surveys, and remedial works across Scotland and beyond, always.

Water flowing through a commercial water treatment system

Water Hygiene & Water Treatment

Expert in-house pre-commission cleaning and pipework sterilisation services for lasting, trusted results always.

HVAC engineer inspecting ventilation ductwork during commissioning

HVAC Commissioning​

Scotland’s largest team of qualified engineers delivering precise HVAC commissioning services.

Cleanroom technician reviewing information on a tablet in a controlled laboratory environment

Clean Air Validation

Specialist testing and validation for cleanrooms, fume cupboards, and biological safety cabinets.